A suitable location and the right connections are the starting point for your MINIFINITY. Before site preparation, the requirements for your configuration must be agreed with your Flagship Store or your certified partner.
Dimensions at a glance
| Area | Dimensions |
|---|---|
| Exterior cladding: length × width | 2,738 × 2,098 mm |
| Width at the upper edge | 2,104 mm |
| Overall height, High version | 950 mm |
| Overall height, Low version | 750 mm |
| Open water surface | 1,886 × 1,489 mm ≈ 2.81 m² |
| Required footprint | 5.744 m² |
These dimensions refer to the specified areas. Additional clearance for access, positioning and servicing must be planned separately.
Weights & area loads
| Condition | HIGH | LOW |
|---|---|---|
| Pool without water | approx. 411 kg | approx. 367 kg |
| Pool filled with water, no occupants | approx. 3,020 kg | approx. 2,414 kg |
| Pool filled with water + 2 people | approx. 3,220 kg | approx. 2,614 kg |
| Pool filled with water + 4 people | approx. 3,420 kg | approx. 2,814 kg |
| Average load per square metre with 4 people | approx. 595 kg/m² | approx. 490 kg/m² |
Preliminary, rounded planning values (13 October 2026). Assumed weight: 100 kg per person. Area load: calculated average over 5.744 m²; not evidence of local support loads.
Location & load-bearing capacity
The base must be suitable, level and have sufficient load-bearing capacity. The assessment must account for the combined weight of MINIFINITY, the water and the users, as well as how this load is distributed over the supporting area. For rooftop terraces, balconies and other structurally sensitive locations, qualified specialists must assess load-bearing capacity and local site requirements.
Important: Structural approval required
Before installation, you must arrange for a qualified structural engineer to check the total weight of your MINIFINITY, including water and occupants, and the permissible load per square metre and load-bearing capacity of your terrace, rooftop terrace or balcony. The proposed location must be expressly approved for this load. The stated average loads do not replace a site-specific structural assessment.
Access & connections
The connections required for your configuration and the arrangements for access, unloading and any necessary lifting equipment must be clarified beforehand. Connection, filling and commissioning follow professional positioning. The technical service area must remain accessible for maintenance and servicing.
Planning information for your configuration
Before site preparation, the confirmed weight and load data, connection requirements and necessary clearances must be established using the technical documentation for your chosen configuration. This overview does not replace the installation instructions or a site-specific technical assessment.